Skip to content
View All Products

Our range includes Weir-style, Radial Diaphragms and Fasteners from Diaphragms Direct®.

Our selection of fittings is meticulously curated to synergise with plastic, rubber tubing and hose systems.

Newman Gaskets meet strict sanitary standards to support product integrity and minimise contamination risk.

Newman O-rings are designed to protect product integrity, prevent contamination, and deliver reliable sealing performance across critical applications.

PharmEquip supplies Alfa Laval UltraPure pumps, engineered specifically for high-purity and ultra-hygienic pharmaceutical processes.

Discover PharmEquip’s range of Alfa Laval tank cleaning equipment, designed to deliver efficient, reliable and validated cleaning performance.

Alfa Laval valve sensing and control units are designed to monitor and regulate flow in fluid handling systems.

Fedegari Case Study: High-Precision Sterilization and Industrial Scale-Up for Revolutionary Ophthalmic Packaging

29 September 2026
fedegari case study

Sterilising sensitive packaging at production scale is one of the toughest problems in pharmaceutical and ophthalmic manufacturing. As the Fedegari specialist for Australia and New Zealand, PharmEquip is sharing a new Fedegari case study, prepared with its client Menicon, showing how a 1 mm contact lens pack with an easy-peel seal has been sterilised for more than 20 years with zero seal failures and zero product recalls.

It covers how Fedegari used counterpressure management based on Dalton’s Law, custom load design and a lab-to-production scale-up method to protect a fragile seal across more than 60,000 lenses per cycle. If your process involves pressure-sensitive packaging, dense loads or moving a validated process from development into production, it’s worth a read.

The full case study, prepared by Fedegari together with Menicon, follows below.


 

Industrialising a 1 mm contact lens flat pack while preserving package integrity and sterility assurance

Introduction

Fedegari is a global strategic partner for sterilization and biodecontamination control processes for pharmaceutical and biotechnology companies. With over 70 years of experience, Fedegari is globally recognized for its customized and innovative approach, providing tailor-made solutions to meet the demands of a highly regulated market, all with one goal: collective well-being. From Technology Transfer to Knowledge Transfer we protect the value of process knowledge from laboratory development to industrial production, this case study explores how Fedegari achieved high-precision sterilization and industrial scale-up for a revolutionary 1 mm “flat pack” contact lens packaging.

This case study explores the market context driving this initiative and highlights Fedegari’s expertise in developing high-precision sterilization processes for revolutionary ophthalmic packaging.

 

Abstract: typical features of the production process

Contact lens manufacturing is a highly sophisticated process demanding absolute sterility, extreme precision, and strict compliance with ophthalmic regulations such as GMP standards. A critical phase is terminal sterilization, which must be achieved without altering the optical properties of the lens or compromising the integrity of increasingly innovative packaging. In this context, monitoring the pressure-temperature balance and the micro-movements of the product during the cycle is essential to prevent packaging stress and ensure a zero-defect output. This paper explores a project that spans both laboratory development and industrial production scale-up, highlighting how deep expertise in sterilization enables a seamless and controlled transition from R&D to full-scale manufacturing.

 

The customer

Menicon Co., Ltd. is a global leader in the ophthalmic industry, serving major markets including Japan, China, Europe, and the USA. Renowned for its innovation, Menicon developed the “flat pack” – the world’s first 1 mm thick contact lens package – which revolutionized the daily disposable market by improving hygiene and portability. Their Singapore facility acts as a global manufacturing hub, producing hundreds of millions of lenses annually.

 

The challenge

Industrialising a 1 mm contact lens flat pack while preserving package integrity and sterility assurance

Menicon’s 1 mm flat pack represents a significant departure from conventional ophthalmic packaging.

Standard blisters typically have a seal strength of 18–25 Newtons, whereas the “easy-peel” flat pack reduced this force to only 5–7 Newtons to improve user convenience. This made the package extremely vulnerable to pressure differentials generated during thermal sterilization.

At the same time, the highly compact magazine configuration, with products stacked only 1 mm apart, introduced additional complexity by challenging uniform steam penetration throughout the load.

The objective was therefore not only to achieve sterilization, but to translate a highly delicate packaging concept into a robust, repeatable and industrially scalable manufacturing process.

 

Why Fedegari

Menicon selected Fedegari not simply for the autoclave technology itself, but for its ability to understand and govern the physical principles affecting the product throughout the sterilization process.

The challenge required precise management of partial pressures according to Dalton’s Law, ensuring that package expansion remained fully controlled during both heating and cooling phases. Fedegari’s expertise in pressure profiling and counterpressure management provided the foundation for protecting the fragile 5–7 Newton seals while maintaining process consistency.

Beyond chamber control, Fedegari contributed to the development of the entire sterilization architecture. Custom magazines, loading trays and trolley structures were specifically designed to support steam penetration and product stability within an extremely dense load configuration.

This process-driven approach enabled Menicon to address challenges that extended well beyond conventional terminal sterilization and established the foundation for the successful industrialization of the flat pack concept.

 

 

Technical focus: Dalton’s Law and blister management

Dalton’s Law and blister management in contact lens sterilisation, explained by Fedegari

 

 

Scale-up: from lab validation to industrial success

A structured scale-up strategy was fundamental to transforming the flat pack concept into a commercially viable manufacturing process.

The journey began with Proof of Principle (POP) activities performed at laboratory scale within Fedegari facilities, where the behaviour of the package was evaluated under controlled sterilization conditions. These studies allowed critical process parameters, pressure profiles and load configurations to be established before industrial implementation.

The objective was not simply to demonstrate sterilization performance in a laboratory environment, but to ensure that the same process behaviour could be reliably reproduced under full production conditions.

By applying the same governing sterilization principles throughout development and manufacturing, Fedegari successfully transferred the validated process to the industrial sterilization systems installed at Menicon’s Singapore production facility.

Fedegari Singapore Tech Center supports sterilisation scale-up from lab development to industrial production

 

Flow

Automated touchless contact lens production line with a Fedegari autoclave at its centre

Menicon’s production process is designed as a fully automated, “touchless” flow where the Fedegari autoclave is strategically placed at the heart of the line.

 

Before Fedegari (Upstream)

  • Molding: Contact lenses are manufactured during the initial molding phase.
  • Primary Packaging (Flat Pack): The lenses are placed into the revolutionary 1 mm thick “flat pack” packaging.
  • Loading into Magazines: The packs are stacked into custom-designed magazines, engineered in collaboration with Fedegari to guarantee optimal steam penetration despite the extremely dense 1 mm spacing between products.
  • Automated Handling: These magazines are an integral part of the production flow and are moved via robotics toward the autoclave, ensuring that operators never have to touch or extract the product manually.
  • Sterilization: The lenses enter the autoclave for terminal sterilization. In this phase, Fedegari’s software provides high-precision control over partial pressures (Dalton’s Law) to prevent the fragile 5-7 Newton seals of the flat pack from bursting during the heating and cooling cycles.
  • Exit from the Autoclave: The magazines exit the autoclave, typically using a two-door system to maintain strict separation between processing zones.
  • Secondary Packaging: The sterilized product moves directly to the secondary packaging stage. This transition is fully automated, maintaining the “touchless” integrity of the entire process.
  • Global Distribution: Once final packaging is complete, the lenses are dispatched to global markets.

In summary, the Fedegari autoclave acts as a critical bridge integrated into the robotic line, connecting lens manufacturing directly to final packaging for global sale.

 

Solution

The solution combined advanced counterpressure management, optimized load architecture and precise control of the interaction between packaging behaviour and sterilization dynamics.

Rather than addressing each challenge independently, these elements were developed as part of a single process strategy aimed at maintaining package integrity, sterilization effectiveness and production efficiency throughout the manufacturing lifecycle. By governing pressure differentials, supporting uniform steam penetration and preserving the stability of the highly delicate flat pack design, the process achieved the robustness required for long-term industrial operation.

 

Outcome

Challenge (Limits in the Process) Fedegari Expertise Solution Result
Packaging Integrity: Risk of 5-7N seals bursting during heating. Super-critical management of pressure profiling and ballasting. Zero seal failures across billions of lenses produced over 20 years.
Steam Penetration: Packs stacked 1 mm apart block steam flow. Year-long collaborative R&D to design custom loading magazines. 100% steam permeation guaranteed for terminal sterilization of high-density loads.
Throughput & Efficiency: Need for mass production without manual handling. Integrated autoclaves into a fully automated robotic line. Total “touchless” process; zero operator contact from molding to secondary packaging.
Contamination & Safety: Strict sterility requirements (Log 12). Precision control of temperature/pressure balance in large chambers. Zero product recalls in two decades of global distribution.
Risk of process variation and loss of reproducibility when transferring critical sterilization parameters from laboratory development to industrial manufacturing. Integrated laboratory-to-industrial scale-up methodology based on common sterilization principles, control philosophy and process understanding. Successful industrialization of a highly sensitive ophthalmic application with full process reproducibility and long-term operational stability.

 

 

Metrics

Contact lens sterilisation results: 60,000+ lenses per cycle, Log 12 reduction, 20 years with zero seal failures

 

Conclusions

Conclusions from Fedegari’s ophthalmic packaging case study on reliable sterilisation at production scale

 

Q&A section

What are the most impactful criticalities in this type of production?

The most critical factors are seal integrity during the expansion phase and ensuring uniform steam penetration in a load where products are extremely close together (1 mm spacing).

How can we support the customer in overcoming them?

Through collaborative R&D and the design of custom magazines and loading structures that optimize steam flow and support the product during micro-movements caused by pressure changes.

Highlight the specific strengths of Fedegari solutions:

Fedegari’s software provides unmatched precision in managing local pressures within a large chamber, which is vital when processing over 60,000 lenses per cycle.

What must be carefully monitored when producing a contact lens?

The pressure-temperature balance must be monitored with extreme care, especially during the heating and cooling phases, to avoid stressing the fragile 5-7 Newton seals.

Source: fedegari.com
Download the PDF version of this case study

 


 

Talk to us about your sterilisation process

PharmEquip is the Fedegari specialist for Australia and New Zealand, sourcing Fedegari sterilisation and contamination control equipment for pharmaceutical and biopharmaceutical manufacturers across both countries.

If you’re working with sensitive packaging, high-density loads or a scale-up from lab to production, our team can talk you through what this case study means for your process and how Fedegari technology could support it.